Wipers
Texwipe TechniCloth® II Wipers
Made of a hydroentangled blend of 55% cellulose and 45% polyester, and treated with ITW Texwipe proprietary ultralow particulate (ULP) finish. ULP finish formulated to resist extraction in commonly used solvents. Flat pack.
| Style | Description | Size | Pack | Qty | |
|---|---|---|---|---|---|
| TX | TechniCloth II | 10 bags/case |
Specifications
Technical Data
| PERFORMANCE CHARACTERISTICS | ||
|---|---|---|
| Property | Typical Value | Text Method* |
| Particles and Fibers | ||
| LPC; ≥0.5 µm | 37 x 106 particles/m2 | 1, TM22 |
| Fibers: >100 µm | 40,000 fibers/m2 | 2, TM22 |
| Nonvolatile Residue | ||
| IPA extractant | 0.02 g/m2 | 1, TM1 |
| DIW Extractant | 0.02 g/m2 | 1, TM1 |
| Ions | ||
| Sodium | 40 ppm | 1, TM18 |
| Potassium | 5 ppm | 1, TM18 |
| Chloride | 24 ppm | 1, TM18 |
| PHYSICAL CHARACTERISTICS | ||
| Property | Typical Value | Test Method* |
| Absorbency | ||
| Sorptive capacity | 260 mL/m2 | 1, TM20 |
| Sorptive rate | 1.2 seconds | 1, TM20 |
| Basis Weight | 67 g/m2 | 1, TM20 |
*Test Methods
1 – “Evaluating Wiping Materials Used in Cleanroom and Other Controlled Environments,” IEST-RP-CC004.3, Institute for Environmental Sciences and Technology, Rolling Meadows, IL, 2004; www.iest.org.
2 – E2090-12, “Standard Test Method for Size-Differentiated Counting of Particles and Fibers Released from Cleanroom Wipers Using Optical and Scanning Electron Microscopy,” ASTM International, West Conshohocken, PA, 2012; www.astm.org.
TM – Refers to Texwipe Test Method – available upon request. Contact Texwipe Customer Service at www.texwipe.com or [email protected] for a copy.
Note: The data in this table represent typical analyses.